SM110/SM100
|
|
|
Electrical
Parameters1 |
|
|
Maximum
power rating, Pmax |
[Watts] |
|
Minimum
power rating, Pmin |
[Watts] |
|
Rated
current, Imp |
[Amps] |
|
Rated
voltage, Vmp |
[Volts] |
|
Short
circuit current, Isc |
[Amps] |
|
Open
circuit voltage, Voc |
[Volts] |
|
Thermal
Parameters |
|
|
Nominal
operating cell temperature2 |
[°C] |
45(+or-)2 |
Change
of Isc with temperature |
|
+1.2mA/°C
(+0.04%/K) |
Change
of Voc with temperature |
|
-0.0775
Volts/°C
(-0.34%/K) |
Qualification
Test Parameters3 |
|
|
Temperature
cycling range |
[°C] |
-40
to +85 |
Humidity,
freeze, damp heat condition |
[%
RH] |
85 |
Maximum
system voltage |
[Volts] |
1000
per ISPRA (EC)
600 per UL1703 |
Wind
loading or surface pressure |
[N/m²]
(lb/sqft) |
[2400]
(50) |
Maximum
distortion4 |
[degrees] |
1.2 |
Hailstone
impact withstand (diameter
@ velocity)
|
[mm
@ m/s]
(in @ MPH) |
25
@ 23
(1.0 @ 52) |
Physical
Parameters |
|
|
Number
of cells in series |
|
72 |
Length |
[mm]
(in) |
1316
(51.8) |
Width |
[mm]
(in) |
660
(25.98) |
Depth
(without box) |
[mm]
(in) |
40
(1.6) |
Weight |
[kg]
(lb) |
11.5
(25.1) |
Warranty5 |
|
|
Power
>or= 90% of minimum power rating above |
[Years] |
10 |
Power
>or= 80% of minimum power |
[Years] |
25 |